5
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS - Comments: OBSERVED FACILITY WITH A BODILY FLUID SPILL KIT AND NO CORRESPONDING CLEAN UP PROCEDURE AND KIT FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS. INSTRUCTED FACILITY TO DEVELOP A CLEAN-UP PROCEDURE AND KIT MAINTAIN APPROPRIATE SUPPLIES THAT CORRESPOND WITH ON-SITE PLAN. MUST KEEP BOTH THE POLICY AND SUPPLIES ON SITE AT ALL TIMES. PRIORITY FOUNDATION VIOLATION #7-38-005. NO CITATION ISSUED.
38
INSECTS, RODENTS, & ANIMALS NOT PRESENT - Comments: OBSERVED LIVE AMERICAN ROACH AND DEAD AMERICAN ROACHES IN REAR PREP AND BASMT STORAGE AREA INSTRUCTED TO CLEAN AND SANITIZE AFFECTED AREAS. RECOMMENDED TO CONSULT WITH PEST CONTROL COMPANY. PRIORITY FOUNDATION #7-38-020(A)
38
INSECTS, RODENTS, & ANIMALS NOT PRESENT - Comments: OBSERVED A 1/4" GAP AT THE BOTTOM OF THE REAR EXIT DOOR IN BSMT STORAGE AREA. MUST PROVIDE A TIGHT-FITTING SEAL AT ALL OUTER OPENINGS TO PREVENT THE ENTRY OF PESTS.
39
CONTAMINATION PREVENTED DURING FOOD PREPARATION, STORAGE & DISPLAY - Comments: OBSERVED NO SPLASHGUARD BETWEEN EXPOSED HAND SINK AND DRAINBOARD OF 3 COMPARTMENT SINK AT BAR. MUST INSTALL A SPLASHGUARD THAT IS SMOOTH AND EASILY CLEANABLE.
47
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: OBSERVED RUSTED STORAGE RACKS ACROSS FROM UTILITY SINK NEAR WALK IN COOLER, INSTRUCTED SURFACES MUST BE SMOOTH AND EASILY CLEANABLE AND MAINTAIN.
48
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: OBSERVED FAUCET AT 3 COMPARTMENT SINK SPOUT NOT LONG ENOUGH TO FILL 1ST BASIN AND 3RD BASIN INSTRUCTED TO REPLACE WITH FAUCET SPOUTMSO IT IS LONG ENOUGH TO FILL ALL BASINS AT 3 COMP SINK.PRIORITY FOUNDATION VIOLATION #7-38-025. NO CITATION ISSUED.
51
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED DRAINPIPE EXCESSIVELY LEAKING UNDER HANDSINK AT BAR. INSTRUCTED TO REPAIR LEAKING DRAINPIPE. PRIORITY VOILATION # 7-38-030(c) NO CITATION ISSUED
51
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED 2 COMP SINK IN REAR PREP FAUCET IS LEAKING, INSTRUCTED TO REPAIR AND MAINTAIN
53
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: OBSERVED NO COVERED RECEPTACLE FOR PROPER DISPOSAL OF SANITARY NAPKINS IN WOMENS WASHROOM. INSTRUCTED TO PROVIDE COVERED WASTE RECEPTACLE.
55
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: OBSERVED FOOD DEBRIS ON FLOOR BEHIND EQUIPMENT, INSTRUCTED TO CLEAN AND MANITAIN.
55
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: OBSERVED MISSING CEILINGS TILE PANELS IN FRONT AND REAR PREP, DISH, AND UTILITY SINK AREA. ALSO NOTED FOOD AND WATER-STAINED CEILING TILES THROUGHOUT PREP AREAS. INSTRUCTED TO REPAIR, REPLACE MISSING PANELS AND/OR REPLACE THE STAINED CEILING TILES.
55
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: NOTED BROKEN, CRAKED FLOOR TILES IN DINING ROOM, FRONT PREP, REAR PREP, DISH AND 2 COMP SINK PREP AREAS, INSTRUCTED TO REPAIR TO CREATE A SMOOTH AND EASILY CLEANABLE SURFACE. MUST MAINTAIN AT ALL TIMES.
56
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: NOTED LIGHTS NOT WORKING IN REAR PREP 2 COMP SINK AREA AND BASEMENT STORAGE, INSTRUCTED TO REPAIR AND MAINTAIN.
56
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: NOTED LIGHT PROTECTIVE SHIELDING MISSING FROM BASEMENT STORAGE AREA, INSTRUCTED TO PROVIDE AND MAINTAIN.
56
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: OBSERVED MECHINANICAL VENTILATION WITH EXCESSIVE DUST, INSTURCTED TO CLEAN AND MAINTAIN.