8
SANITIZING RINSE FOR EQUIPMENT AND UTENSILS: CLEAN, PROPER TEMPERATURE, CONCENTRATION, EXPOSURE TIME - Comments: Equipment and utensils should get proper exposure to the sanitizing solution during the rinse cycle. Bactericidal treatment shall consist of exposure of all dish and utensil surfaces to a rinse of clean water at a temperature of not less than 180F. OBSERVED DISHMACHINE SANITIZING AT IMPROPER TEMPERATURE. OBSERVED FINAL RINSE TEMPERATURE AT 160F ACCORDING TO THE TEMPERATURE GAUGE ON THE MACHINE. UNIT TAGGED HELD FOR INSPECTION BY CDPH. MUST MAINTAIN FINAL RINSE ABOVE 180F. ALSO, LOW TEMPERATURE GLASS WASHER HAD 0 PPM CHLORINE FOR THE FINAL RINSE. MANAGEMENT INSTRUCTED TO REPAIR SO THAT FINAL RINSE SANITIZES AT 100 PPM CHLORINE. UNIT TAGGED HELD FOR INSPECTION. CRITICAL VIOLATION 7-38-030.
16
FOOD PROTECTED DURING STORAGE, PREPARATION, DISPLAY, SERVICE AND TRANSPORTATION - Comments: All food should be properly protected from contamination during storage, preparation, display, service, and transportation. FOOD (ICE) NOT PROTECTED DURING STORAGE INSIDE OF THE ICE MACHINE. OBSERVED MOLD GROWTH ON INTERIOR CONTACT SURFACES OF THE ICE MACHINE. UNIT TAGGED HELD FOR INSPECTION. MUST TURN OFF MACHINE, REMOVE ICE AND HAVE INTERIOR OF UNIT CLEANED AND SANITIZED. SERIOUS VIOLATION 7-38-005A.
18
NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS - Comments: All necessary control measures shall be used to effectively minimize or eliminate the presence of rodents, roaches, and other vermin and insects on the premises of all food establishments, in food-transporting vehicles, and in vending machines. EVIDENCE OF INSECTS OBSERVED IN THE PREP AREA. OBSERVED 5 LIVE COCKROACHES ON THE WALL, FLOOR AND EQUIPMENT IN THE PREP AREA AND DISHWASH AREA. ALSO OBSERVED REAR EXIT DOOR FROM THE 1ST FLOOR PREP AREA NOT RODENT PROOFED. MANAGEMENT INSTRUCTED TO RODENT PROOF THE EXIT DOOR. ADDITIONAL PEST CONTROL SERVICE IS NEEDED TO ELIMINATE ALL PEST ACTIVITY. SERIOUS VIOLATION 7-38-020.
24
DISH WASHING FACILITIES: PROPERLY DESIGNED, CONSTRUCTED, MAINTAINED, INSTALLED, LOCATED AND OPERATED - Comments: 3 COMPARTMENT SINK IN THE DISHROOM IS NOT MAINTAINED. OBSERVED NO HOT WATER AVAILABLE AT THE RIGHT FAUCET. THE LEFT FAUCET HAS HOT WATER, BUT IT ONLY REACHES THE LEFT AND MIDDLE COMPARTMENTS. MUST REPAIR OR ADD FAUCET EXTENSION SO THAT THE RIGHT COMPARTMENT CAN BE FILLED WITH WATER. SERIOUS VIOLATION 7-38-030.
29
PREVIOUS MINOR VIOLATION(S) CORRECTED 7-42-090 - Comments: A separate and distinct offense shall be deemed to have been committed for each Minor violation that is not corrected upon re-inspection by the health authority. PREVIOUS MINOR VIOLATION FROM REPORT #114612 ON 10/22/10 NOT CORRECTED: 34/01- The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. FLOOR AND FLOOR TILES IN POOR REPAIR/DAMAGED ALONG 1ST FLOOR PREP AREA COOKLINE, BAR AREA, DISHMACHINE ROOM AND LOWER LEVEL PREP AREA. MUST REPAIR AND MAINTAIN ALL DAMAGED FLOOR/FLOOR TILES THROUGHOUT, FLOOR MUST BE SMOOTH AND EASY TO CLEAN/KEEP DRY. SERIOUS VIOLATION 7-42-090.
30
FOOD IN ORIGINAL CONTAINER, PROPERLY LABELED: CUSTOMER ADVISORY POSTED AS NEEDED - Comments: All food not stored in the original container shall be stored in properly labeled containers. MUST LABEL AND DATE ALL PREPARED FOODS IN THE COOLERS.
32
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED - Comments: All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. REPAINT OR REPLACE THE RUSTED WIRE STORAGE RACKS IN THE PREP COOLER NEXT TO THE EXPOSED HANDSINK.
33
FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS - Comments: All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. DETAIL CLEAN THE VENTILATION HOOD FILTERS ABOVE THE COOKING EQUIPMENT AND THE GAS LINES BEHIND THE EQUIPMENT.
34
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED - Comments: The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. DETAIL CLEAN THE FLOOR UNDER THE COOKING EQUIPMENT AND THE WALK-IN FREEZER..
35
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS - Comments: The walls and ceilings shall be in good repair and easily cleaned. REPAIR THE BASEBOARD TILES AROUND BOTH PREP AREAS, DISHROOM. REPAIR THE FRP BOARD NEXT TO THE EXPOSED HANDSINK IN THE PREP AREA AND IN THE DISHROOM AND BASEMENT PREP AREA. DETAIL CLEAN THE WALL BEHIND THE DEEP FRYER, BROILER. REPAIR THE FRP BOARD BEHIND THE BROILER. REPLACE THE MISSING CEILING TILE IN THE DISHROOM. DETAIL CLEAN THE LIGHT SHIELDS IN BOTH PREP AREAS.
36
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities. REPLACE THE MISSING OR CRACKED LIGHT SHIELDS IN THE PREP AREA.
37
TOILET ROOM DOORS SELF CLOSING: DRESSING ROOMS WITH LOCKERS PROVIDED: COMPLETE SEPARATION FROM LIVING/SLEEPING QUARTERS - Comments: Toilet rooms shall be completely enclosed and shall be vented to the outside air or mechanically ventilated. PROVIDE A SELF-CLOSING DOOR DEVICE FOR THE EMPLOYEE RESTROOM IN THE BASEMENT.
38
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED - Comments: REPAIR THE LEAKING CONDENSER DRIP PAN IN THE PRODUCE WALK-IN COOLER IN THE BASEMENT. THE ICE MACHINE IS DRAINING ONTO THE FLOOR OF THE BASEMENT. MUST ROUTE DRAIN LINE TO A FLOOR DRAIN.